33kV Circuit Operational Data Monthly

Published by UK Power Networks, Company number 3870728

About this dataset

Introduction UK Power Network maintains the 132kV voltage level network and below. An important part of the distribution network is distributing this electricity across our regions through circuits. Electricity enters our network through Super Grid Transformers at substations shared with National Grid we call Grid Supply Points. It is then sent at across our 132 kV Circuits towards our grid substations and primary substations. From there, electricity is distributed along the 33 kV circuits to bring it closer to the home. These circuits can be viewed on the single line diagrams in our Long-Term Development Statements (LTDS) and the underlying data is then found in the LTDS tables . Care is taken to protect the private affairs of companies connected to the 33 kV network, resulting in the redaction of certain circuits. Where redacted, we provide monthly statistics to continue to add value where possible. Where monthly statistics exist but half-hourly is absent, this data has been redacted. This dataset provides monthly statistics across these named circuits from 2021 through to the previous month across our license areas. The data is aligned with the same naming convention as the LTDS for improved interoperability. To find half-hourly current and power flow for the circuit you are looking for, use the ‘ltds_line_name’ that can be cross referenced in the EPN and SPN 33kV Circuits Half Hourly data. If you want to download all this data, it is perhaps more convenient from our public sharepoint: Sharepoint This dataset is part of a larger endeavour to share more operational data on UK Power Networks assets. Please visit our Network Operational Data Dashboard for more operational datasets. Methodological Approach The dataset is not derived, it is the measurements from our network stored in our historian. The measurement devices are taken from current transformers attached to the cable at the circuit breaker, and power is derived combining this with the data from voltage transformers physically attached to the busbar. The historian stores datasets based on a report-by-exception process, such that a certain deviation from the present value must be reached before logging a point measurement to the historian. We extract the data following a 30-min time weighted averaging method to get half-hourly values. Where there are no measurements logged in the period, the data provided is blank; due to the report-by-exception process, it may be appropriate to forward fill this data for shorter gaps. We developed a data redactions process to protect the privacy or companies according to the Utilities Act 2000 section 105.1.b , which requires UK Power Networks to not disclose information relating to the affairs of a business. For this reason, where the demand of a private customer is derivable from our data and that data is not already public information (e.g., data provided via Elexon on the Balancing Mechanism), we redact the half-hourly time series, and provide only the monthly averages. This redaction process considers the correlation of all the data, of only corresponding periods where the customer is active, the first order difference of all the data, and the first order difference of only corresponding periods where the customer is active. Should any of these four tests have a high linear correlation, the data is deemed redacted. This process is not simply applied to only the circuit of the customer, but of the surrounding circuits that would also reveal the signal of that customer. The directionality of the data is not consistent within this dataset. Where directionality was ascertainable, we arrange the power data in the direction of the LTDS "from node" to the LTDS "to node". Measurements of current do not indicate directionality and are instead positive regardless of direction. In some circumstances, the polarity can be negative, and depends on the data commissioner's decision on what the operators in the control room might find most helpfu

Live preview

The first rows, fetched from Opendatasoft hub when you open this page.

Loading the first rows from the source…

33kV Circuit Operational Data Monthly · Open Data Finder