Skip to content
Open Data Finder
data.gov.au

Effects of climate change and the herbicide diuron on Photosystem II activity of the tropical seagrass Halophila ovalis (NESP TWQ 2.1.6, AIMS)

Published by Australian Ocean Data Network

About this dataset

The aim of this study was to investigate the effects of the herbicide diuron and climate change on the Photosystem II activity of the seagrass Halophila ovalis. The 3 climate conditions were: ambient (28.5 °C, 398 µatm), 2050 (29.5 °C, 682 µatm) and 2100 (30.5 °C, 873 µatm). This dataset consists of one data file (spreadsheet) from a 2-week experiment, containing 5 diuron concentrations and 3 climate change scenarios. Each tab contains photosynthetic yield data at each time point: 0 d, 2 d, 7 d and 14 d under each of the diuron and climate change treatments. The first 4 tabs are effective quantum yield data and the last tab consists of maximum quantum yield data. Methods: Approach and experimental design Seagrasses (H. ovalis) were exposed for 14 days to three different seawater pCO2 and temperature conditions (398 µatm, 28.5 °C, 682 µatm, 29.5 °C and 873 µatm, 30.5 °C) and four elevated concentrations of diuron (0.3, 1, 3 and 10 µg l-1 nominal concentrations), including a solvent control. H. ovalis were placed in custom 3 l acrylic chambers (15 cm diameter x 19 cm height, working volume 2.5 l) in water baths with the appropriate level of pCO2 bubbling in each chamber. Stock solutions of diuron (10 mg l-1) were prepared in milli Q water (0.5 µm) using a < 0.03% w/w ethanol solvent carrier. Diuron was delivered from 60 L header tanks to the experimental chambers using peristaltic pumps (Masterflex L/S and Ismatec IPC 12) for a turnover rate of at least once per day. Three ramets of H. ovalis were placed in each experimental chamber and three independent replicate chambers were used for each diuron concentration and each climate change scenario. Chambers were randomised to prevent any environmental effects associated with the laboratory. H. ovalis were illuminated over 13h cycles (Aqua Illumination LED Hydra) with ramping up for the first three hours to approximately 200 µmol m-2 s-1 then down to darkness over the last 3 hours. Irradiance was measured with a Licor LI-250A meter with LI-190R quantum sensor (Li-Cor, Lincoln, USA). Parameters (pH, salinity and dissolved oxygen) were measured five times during the duration of the 14 d experiment. Water temperature and pCO2 levels were controlled by a programmable logic controller (PLC) and measured every ten minutes. Salinity was measured via a handheld meter (Horiba LAQUAact PC110), pH was measured with a multimeter (HQ40d equipped with Intellical PHC301 pH electrode (Hach, USA) and oxygen concentration was determined with a handheld meter (HQ30d equipped with Intellical LDO101 oxygen probe (Hach, USA). Chlorophyll fluorescence (effective quantum yield, deltaF/Fm’) were taken just prior to the start of exposure and at 2 days, 7d and 14d exposure and maximum quantum yields (Fv/Fm) were taken at 14d exposure using an imaging PAM fluorometer (iPAM, WALZ, Germany). Data-MAXI software (Imaging Win, Walz, Germany) was used to select a single area of interest (AOI) on one leaf per ramet. Minimum fluorescence (F with illuminated samples and F0 with dark-adapted samples) was initiated and recorded by applying a weak pulse-modulated red measuring light (650 nm, 0.15 µmol photons m-2s-1). To quantify light adapted maximum fluorescence (Fm’) a short pulse (800 ms) of saturating actinic light (>3000 µmol photons m-2s-1) was applied and the effective quantum yield of PSII calculated from deltaF/Fm’ = (Fm' – F)/Fm'. Actinic light was set to approximately 100 µmol photons m-2s-1 for 3 min to generate a moderate level of photochemical quenching. To calculate the maximum quantum yield of PSII (Fv/Fm), seagrass ramets were dark adapted for approximately 30 min and F0 and Fm measured, as above, from Fv/Fm = (Fm – F0) / Fm. Pesticide concentrations (2-3 samples) were taken at the start and end of the experiment and analysed by high performance liquid chromatography-mass spectrometry (HPLC-MS/MS). The geometric mean from measured start and end concentrations (time weighted average) was assigned as the ‘

Effects of climate change and the herbicide diuron on Photosystem II activity of the tr… · Open Data Finder