Survey of water quality and suspended solid metals for ten (10) sites around Saibai and Boigu Islands in the Torres Strait, June 2018 (NESP TWQ 2.2.2, CSIRO)
Published by Australian Ocean Data Network
About this dataset
This dataset summarises the results of a survey of water quality and suspended solid metal data for ten (10) sites around Saibai and Boigu Islands in the Torres Strait during November 2018. This is the second survey for this project, where the first survey identified the area around Saibai as having elevated metal concentrations compared to other areas of the Torres Strait. This survey was conducted to investigate this finding. Water samples were collected from five sites around Saibai Island and five sites around Boigu Island. METHODS: Sample Collection Sampling was conducted by the CSIRO team with the assistance of TSRA staff from on-board the TSRA patrol vessels stationed at both islands. It was not possible to deploy a tender off the main boat, so water samples were collected from the back of the patrol vessel using 5 L acid washed containers. Water samples were collected by immersing the container by hand to a depth of approximately 0.5 m. Powder free plastic gloves were worn during the sampling operation. The containers were filled and rinsed twice with water from the Location prior to filling. It should be noted that this method of sampling is not recommended for the accurate determination of dissolved zinc in marine waters as many aluminium hulled boats and outboard motors are equipped with zinc sacrificial anodes that release dissolved zinc into solution. For quality control purposes, a field blank was prepared during both the Saibai and Boigu legs of the field trip. Duplicate samples were collected at sites S1, 8 and B1. Salinity and pH were measured using an Orion Star A329 portable meter (Thermo Scientific). Sample pH was measured using a Thermo Scientific Orion Gel-Filled ROSS pH Ultra Triode Electrode (8107UWMMD) that was calibrated using pH 4.00, 7.00 and 10.00 buffers. Salinity was measured using a Thermo Scientific Orion Conductivity Cell (013010MD) that was calibrated using KCl conductivity standards. Water samples were transported back to the Island and were processed within five hours of collection in a designated clean area free of dust and other conspicuous sources of metal contamination. As a precaution against sample contamination, surfaces coming into contact with sample containers or lab apparatus were covered with clean plastic. Pre-weighed 0.45 µm membrane filters were used for sample filtration and were retained for particulate metals analysis of suspended sediments. The water and sediment samples were stored chilled and ‘hand carried’ back to the CSIRO laboratories in Sydney for analysis of dissolved and TSS-bound metals. Water sample processing Water samples for analysis of trace metals were vacuum filtered through acid-washed 0.45 µm Millipore membrane filters using an acid washed polycarbonate filtration apparatus (Sartorius). The filtration assemblies were further cleaned before processing each sample by first filtering a 100 mL volume of 10% v/v nitric acid solution followed by two 150 mL volumes of deionised water, and finally, a 50 mL volume of sample. For each volume of these solutions the filtration rig was held on an angle and rotated both before and after filtration so that the solutions came into contact with all surfaces of the top and bottom compartments of the apparatus to ensure rigorous rinsing / pre-treatment was achieved. The 50 mL aliquot of sample used to pre-clean the filtration rig was poured into the 1 L acid washed Nalgene filtrate receiving bottle, shaken to pre-treat the bottle, and discarded to waste. The sample was then filtered and the filtrate transferred into the receiving bottle. Approximately 900 mL of each sample filtrate was retained for analysis. Filtrates were then preserved by addition of 2 mL/L of concentrated nitric acid (Merck Tracepur). For the field blanks, approximately half of the 1L sample was filtered and preserved. The remaining 500 mL was acidified and retained for subsequent analysis. The difference between the filtered and unfiltered field blanks